- If concrete pad is required, the guardrail post is extracted first from the footing.
- A square pit by the dimension of 300 mm x 300 mm x 200 mm (as shown in the drawing) is dug.
- The guardrail post then place into the pit, suspended to the required height. String can be used to ensure uniform level is achieved on all the selected raised guardrails.
- Concrete grade 20 is then poured into the pit, properly compacted and let to cure for 3 days.
Showing posts with label guardrail. Show all posts
Showing posts with label guardrail. Show all posts
Labels:
guardrail
Concrete Pad
Posted by
Engineer Malaysia
Guardrail Works
Guardrail Jacking
- Guardrail to be raised is demarcated and confirmed at site with the Engineer representative.
- Depending on type of footing surface, the height of post shall be 710 mm for concrete surface and 800 mm for non-concrete surface. The following drawing shown the final height of guardrail as intended after the jacking.
Guardrail Jacking (using heavy duty hydraulic jack or chain block)
- The equipment is positioned adjacent to the identified post.
- Manually, the post is raised to the required height as mentioned in (ii) above.
- Upon achieving the required height, the footing of guardrail post is properly compacted as to ensure that the post shall not ‘slip down’.